TLK300
COD. TLK300
The telemetry systems allow for an immediate intervention in case of fault, thanks to the radio station remote control. Equipment great flexibility makes it possible to control a high number of devices or to modify the station layout.
FEATURES
The image of this layout is purely demonstrative and may change without notice.
- Professional Telemetry System at SNMP V 2 level for real time control.
- Compatibile with all RVR scalable transmitters: Modular (air and liquid cooled) and Hot Plug-in.
- Can remote single and dual drive transmitters.
- Integrates several interface and protocols for transmitter's connection: RS232/RS475/I2C.
- Multiple connectivity: over IP, GSM.
- RJ45 for LAN connections, antenna for RF input for the monitor.
- Front panel with leds indicating the operating status of the system for immediate diagnosis.
- Universal Power supply.
- Can be powered with an external DC source (15-24V) to assure continuity in case of main power failure.
- Boards and main components are assembled separately for easy maintenance and upgrade.
TLK300 | ||||
Parameter | U.M. | Value | Notes | |
GENERALS | ||||
Ambient working temperature | -10 °C to + 50 °C / 95% | Relative humidity non condensing | ||
POWER REQUIREMENTS | ||||
AC Power input | AC Supply Voltage | VAC | 80 - 260 | Full Range Monophase |
Active Power Consumption | W | 25 | ||
Connector | VDE IEC Standard | |||
DC Power input | DC Supply Voltage | VDC | 12 | |
DC Current | < 3 a | |||
MECHANICAL DIMENSIONS | ||||
Phisical dmensions | L x H x W | mm / inch | 483 / 19 | EIA Rack |
mm / inch | 44 / 3 1/2 | 1HE | ||
Weight | kg | About 4,3 | ||
Cooling | Convection cooling | |||
Acoustic noise | dBA | 0 | ||
INTERFACES | ||||
Signalling LEDS | Yes | |||
Display | 40X2 Alphanumerical | No | ||
Push buttons | 4 (UP, DOWN, ENTER, ESC) | No | ||
USB | TELECON Protocol | Yes | ||
RS232 | TELECON Protocol | Yes | ||
RS485 | PLUG-IN Protocol | Yes | (Only on TX PLUG-IN CA versions) | |
I2C | Yes | |||
RJ45 | LAN | Yes | (Only on WEB versions) | |
10/100 base-T Ethernet LAN | Yes | |||
HTTP and AJAX | Status and configuration can be accessible from any internet browser on a PC or smartphone | |||
SMTP | Alarm notification events sends via emails (up to 4 independent address can be defined) | |||
SIM slot & ANTENNA | Yes | (Only on GSM versions) | ||
FUSES | ||||
On mains | 1 External fuse F 1 A F - 5X20 mm | |||
On service | X | |||
On PA Supply | X | |||
On driver supply | X |