TX04KSS PLUG-IN NEXT GENERATION
COD. TX04KSS-60D44/EPS
Puissance: 4.000W
4.000W PLUG-IN Next Gen System.
FEATURES
• Tunable over entire FM band (87.5 – 108 MHZ), without tuning.
• Overall efficiency better than 71-73%.
• Hot-pluggable and broadband power amplifier modules.
• High redundancy guaranteed.
• Each amplifier module provides Automatic Power Control.
• Each module has its own hot plug-in fans set.
• Suitable for mono & stereo broadcast operations.
• Protection against high VSWR, overdrive, overcurrent and overtemperature.
• Compliance to IEC safety standards.
• Compliance to ETSI – CCIR – FCC standards.
• Entire transmitter can be switched off through an emergency button.
• All measurement and working parameters are displayed on front panel.
• Remotely controllable by telemetry system.
• Design for 24/7 non-stop operation.
• The transmitter include an integrated system for automatic and manual switching between two exciters.
In Automatic mode the changeover is activated when active power of exciter falls below 3dB.
EPS:
• Each power supply “PS" can be removed or plugged without turning off the transmitter.
•The transmitter is capable of generating an output power with ample margin thanks to oversized power supplies.
• By installing an additional PS, the transmitter will operate at full power in the event of a single PS failure, eliminating the need for derating.
• Each PS features an automatic magnetic switch preventing short circuits and ensuring uninterrupted signal broadcasting.
• The power stream generated by these PS are distributed in parallel to all RF modules; consequently if one
power supply fails all RF modules maintain balanced operation.
• The transmitter’s CCU oversee continuously the operational status of each individual power supply.
• In the event of a failure the "ECM" electronic control module will optimize the transmitter efficiency.
• In an empty slot an additional power supply can be turned on so in the
event of a power supply failure there will be no reduction in power. It is a N+1 PLS system . Only from 4 to 10kW(option)
• Tunable over entire FM band (87.5 – 108 MHZ), without tuning.
• Overall efficiency better than 71-73%.
• Hot-pluggable and broadband power amplifier modules.
• High redundancy guaranteed.
• Each amplifier module provides Automatic Power Control.
• Each module has its own hot plug-in fans set.
• Suitable for mono & stereo broadcast operations.
• Protection against high VSWR, overdrive, overcurrent and overtemperature.
• Compliance to IEC safety standards.
• Compliance to ETSI – CCIR – FCC standards.
• Entire transmitter can be switched off through an emergency button.
• All measurement and working parameters are displayed on front panel.
• Remotely controllable by telemetry system.
• Design for 24/7 non-stop operation.
• The transmitter include an integrated system for automatic and manual switching between two exciters.
In Automatic mode the changeover is activated when active power of exciter falls below 3dB.
EPS:
• Each power supply “PS" can be removed or plugged without turning off the transmitter.
•The transmitter is capable of generating an output power with ample margin thanks to oversized power supplies.
• By installing an additional PS, the transmitter will operate at full power in the event of a single PS failure, eliminating the need for derating.
• Each PS features an automatic magnetic switch preventing short circuits and ensuring uninterrupted signal broadcasting.
• The power stream generated by these PS are distributed in parallel to all RF modules; consequently if one
power supply fails all RF modules maintain balanced operation.
• The transmitter’s CCU oversee continuously the operational status of each individual power supply.
• In the event of a failure the "ECM" electronic control module will optimize the transmitter efficiency.
• In an empty slot an additional power supply can be turned on so in the
event of a power supply failure there will be no reduction in power. It is a N+1 PLS system . Only from 4 to 10kW(option)
TX04KSS/60D44/EPS | ||
Parameter | Value | |
GENERALS | ||
RF Output Power | 4kW + 10% | |
Frequency Range | 87,5 – 108 MHz | |
Driver power for rated output | 30W | |
VSWR | 1.4:1 with automatic fold-back at higher VSWR | |
Asynchronous AM S/N Ratio | Typically >70dB | |
Synchronous AM S/N Ratio | Typically > 55dB | |
Harmonics suppression and Spurious | Typically <85db | 85db>|
RF Harmonics | Exceeds ETSI/CCIR/FCC requirements | |
RF Spurious | Exceeds ETSI/CCIR/FCC requirements | |
Environmental working conditions | -10 °C to + 50 °C / 95% relative Humidity non condensing | |
POWER REQUIREMENTS | ||
AC Power Input | AC Supply Voltage | 400V ±10% AC Three-Phase 3F+N |
230V ±10% AC Three-Phase 3F+N | ||
230V ±10% AC Mono-Phase 50/60 Hz | ||
Active Power Consuption | about 5.600W | |
Power factor | > 0.95 | |
Overall Efficiency | 71/73 % | |
Connector | Terminal Block Standard | |
MECHANICAL DIMENSIONS | ||
Phisical Dimensions | L x H x W | 40u :685 mm x 1935 mm x 1000 mm 32u:685 mm x 1620 mm x 1000 mm |
Weight | about 240 kg | |
Cooling | Forced, with internal fan | |
Acoustic Noise | <75 dba | 75>|
OUTPUTS | ||
RF Output | 50 Ohm (7/8 or 1+5/8 EIA flange type) |